bond0: Invalid MTU 9000 requested, hw max 1500 with kernel 4.8 / 4.10 in XENIAL LTS
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
Linux |
Confirmed
|
Medium
|
|||
linux (Ubuntu) |
Triaged
|
Medium
|
Unassigned | ||
Xenial |
Confirmed
|
Undecided
|
Unassigned | ||
Yakkety |
Fix Released
|
Medium
|
Jesse Sung | ||
Zesty |
In Progress
|
Medium
|
Jesse Sung | ||
linux-hwe (Ubuntu) |
Fix Released
|
Undecided
|
Unassigned | ||
Xenial |
Fix Released
|
Undecided
|
Unassigned | ||
Yakkety |
Fix Committed
|
Undecided
|
Unassigned | ||
Zesty |
Confirmed
|
Undecided
|
Unassigned | ||
linux-hwe-edge (Ubuntu) |
Confirmed
|
Undecided
|
Unassigned | ||
Xenial |
Confirmed
|
Undecided
|
Unassigned | ||
Yakkety |
Fix Committed
|
Undecided
|
Unassigned | ||
Zesty |
Confirmed
|
Undecided
|
Unassigned |
Bug Description
Since I upgraded the kernel from linux-image-
It seems to be known bug already fixed: https:/
# ip l sh eno49
2: eno49: <BROADCAST,
link/ether 5c:b9:01:8a:61:e9 brd ff:ff:ff:ff:ff:ff
# ip l sh eno50
3: eno50: <BROADCAST,
link/ether 5c:b9:01:8a:61:e9 brd ff:ff:ff:ff:ff:ff
# ip l sh bond0
6: bond0: <BROADCAST,
link/ether 5c:b9:01:8a:61:e9 brd ff:ff:ff:ff:ff:ff
# ip l set mtu 9000 bond0
RTNETLINK answers: Invalid argument
root@controller
Apr 4 19:36:28 controller002 kernel: [ 8869.077853] bond0: Invalid MTU 9000 requested, hw max 1500
# modinfo ixgbe
filename: /lib/modules/
version: 4.4.0-k
license: GPL
description: Intel(R) 10 Gigabit PCI Express Network Driver
# modinfo bonding
filename: /lib/modules/
author: Thomas Davis, <email address hidden> and many others
description: Ethernet Channel Bonding Driver, v3.7.1
version: 3.7.1
CVE References
no longer affects: | vlan (Ubuntu) |
description: | updated |
no longer affects: | neutron |
information type: | Public → Public Security |
information type: | Public Security → Public |
summary: |
bond0: Invalid MTU 9000 requested, hw max 1500 with kernel 4.10 (or - 4.8.0-49) + 4.8.0-49, xenial-hwe) |
tags: | added: canonical-bootstack |
summary: |
- bond0: Invalid MTU 9000 requested, hw max 1500 with kernel 4.10 (or - 4.8.0-49, xenial-hwe) + bond0: Invalid MTU 9000 requested, hw max 1500 with kernel 4.8 / 4.10 in + XENIAL LTS |
Changed in linux (Ubuntu Yakkety): | |
status: | In Progress → Fix Committed |
Changed in linux-hwe (Ubuntu Yakkety): | |
status: | Confirmed → Fix Committed |
Changed in linux-hwe-edge (Ubuntu Yakkety): | |
status: | Confirmed → Fix Committed |
no longer affects: | linux-meta-hwe (Ubuntu) |
no longer affects: | linux-meta-hwe (Ubuntu Yakkety) |
no longer affects: | linux-meta-hwe (Ubuntu Zesty) |
tags: |
added: verification-done-yakkety removed: verification-needed-yakkety |
Changed in linux: | |
importance: | Unknown → Medium |
status: | Unknown → Confirmed |
Bond0 interface doesn't accept MTU higher than 1500.I can set MTU perfectly fine for the slave devices. Recreating the bond0 didn't help to up the MTU.
05:00.0 Ethernet controller: Intel Corporation 82599ES 10-Gigabit SFI/SFP+ Network Connection (rev 01)
05:00.1 Ethernet controller: Intel Corporation 82599ES 10-Gigabit SFI/SFP+ Network Connection (rev 01)
[ 1626.840818] bond0: Invalid MTU 9000 requested, hw max 1500
[ 1668.913497] ixgbe 0000:05:00.0 enp5s0f0: changing MTU from 1500 to 9000
[ 1669.176015] ixgbe 0000:05:00.0 enp5s0f0: speed changed to 0 for port enp5s0f0
[ 1669.237523] ixgbe 0000:05:00.0 enp5s0f0: detected SFP+: 5
[ 1669.487920] ixgbe 0000:05:00.0 enp5s0f0: NIC Link is Up 10 Gbps, Flow Control: RX/TX
[ 1675.591234] ixgbe 0000:05:00.1 enp5s0f1: changing MTU from 1500 to 9000
[ 1675.855232] ixgbe 0000:05:00.1 enp5s0f1: speed changed to 0 for port enp5s0f1
[ 1675.911259] ixgbe 0000:05:00.1 enp5s0f1: detected SFP+: 6
[ 1676.159087] ixgbe 0000:05:00.1 enp5s0f1: NIC Link is Up 10 Gbps, Flow Control: RX/TX
[ 1684.745389] bond0: Invalid MTU 9000 requested, hw max 1500
Bonding Mode: IEEE 802.3ad Dynamic link aggregation
Transmit Hash Policy: layer3+4 (1)
MII Status: up
MII Polling Interval (ms): 0
Up Delay (ms): 0
Down Delay (ms): 0
802.3ad info
LACP rate: slow
Min links: 0
Aggregator selection policy (ad_select): stable
System priority: 65535
System MAC address: 90:e2:ba:15:68:20
Active Aggregator Info:
Aggregator ID: 2
Number of ports: 2
Actor Key: 13
Partner Key: 221
Partner Mac Address: 02:1c:73:b2:9a:29
Slave Interface: enp5s0f0
MII Status: up
Speed: 10000 Mbps
Duplex: full
Link Failure Count: 0
Permanent HW addr: 90:e2:ba:15:68:20
Slave queue ID: 0
Aggregator ID: 2
Actor Churn State: none
Partner Churn State: none
Actor Churned Count: 0
Partner Churned Count: 0
details actor lacp pdu:
system priority: 65535
system mac address: 90:e2:ba:15:68:20
port key: 13
port priority: 255
port number: 1
port state: 61
details partner lacp pdu:
system priority: 32768
system mac address: 02:1c:73:b2:9a:29
oper key: 221
port priority: 16000
port number: 373
port state: 61
Slave Interface: enp5s0f1
MII Status: up
Speed: 10000 Mbps
Duplex: full
Link Failure Count: 0
Permanent HW addr: 90:e2:ba:15:68:21
Slave queue ID: 0
Aggregator ID: 2
Actor Churn State: none
Partner Churn State: none
Actor Churned Count: 0
Partner Churned Count: 0
details actor lacp pdu:
system priority: 65535
system mac address: 90:e2:ba:15:68:20
port key: 13
port priority: 255
port number: 2
port state: 61
details partner lacp pdu:
system priority: 32768
system mac address: 02:1c:73:b2:9a:29
oper key: 221
port priority: 17000
port number: 33141
port state: 61
Settings for enp5s0f0:
10000baseT/ Full
10000baseT/ Full
Supported ports: [ FIBRE ]
Supported link modes: 1000baseT/Full
Supported pause frame use: Symmetric
Supports auto-negotiation: Yes
Advertised link modes: 1000baseT/Full
Advertised pause frame use: Symmetr...