LEDs not working properly during migration
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
OEM Priority Project |
Fix Released
|
High
|
Woodrow Shen | ||
Bionic |
New
|
Undecided
|
Unassigned | ||
ledmon (Ubuntu) |
Fix Released
|
Low
|
Unassigned |
Bug Description
Description:
LEDs do not work properly during migration with ledmon-
Steps to reproduce:
1. Launch ledmon
# ledmon ?all
2. Create RAID container and volume
# mdadm --create /dev/md/imsm0 --metadata=imsm --raid-devices=3 /dev/sdb /dev/sdc /dev/sda ?run
# mdadm --create /dev/md/
3. Add spare to RAID volume.
# mdadm --add /dev/md/imsm0 /dev/sdj
4. Begin grow from Raid5 with 3 devices to Raid5 with 4 devices.
# mdadm ?grow /dev/md/imsm0 ?raid-devices=4
5. Check if LEDs are indicating proper RAID status.
Expected results:
LEDs are indicating Rebuild status.
Actual results:
LEDs are showing Normal status.
Upstream commit that fixes that:
Recognize RAID volume under reshape as DEVICE_TYPE_VOLUME
https:/
affects: | ledmon (Ubuntu) → oem-priority |
Changed in oem-priority: | |
importance: | Undecided → High |
Changed in oem-priority: | |
assignee: | nobody → Woodrow Shen (woodrow-shen) |
Changed in ledmon (Ubuntu): | |
importance: | Undecided → Low |
Changed in ledmon (Ubuntu): | |
status: | New → Fix Released |
tags: | added: focal |
Changed in oem-priority: | |
status: | Confirmed → Fix Released |
Status changed to 'Confirmed' because the bug affects multiple users.