0273 overly agressive thermal step down

Bug #2037687 reported by Full Name
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Flashlight Firmware Repository
Fix Released
High
Selene ToyKeeper

Bug Description

I have a D4V2 (0273/single channel/boost/519a) that I updated with anduril.2023-05-17.noctigon-dm11-boost.hex
After doing so I found that when ever using turbo or anything over around 50% it will aggressively ramp down even when the light is barely warm to the touch. Cooling the light off seems to have no effect.
I have factory reset it, and verified it's calibration is in the right ballpark. I have tried increasing the step down limit all the way to 70C with no effect.

Flashing back to anduril.2022-10-21.noctigon-dm11-12v.hex fixes the behavior - so not a show stopping issue.

Revision history for this message
Full Name (realmode) wrote :

Newest updates have resolved this issue.

Revision history for this message
Selene ToyKeeper (toykeeper) wrote :

> Newest updates have resolved this issue.

Ah, yeah. This bug was fixed 13 days after the firmware you were using. It was pretty short-lived.

Changed in flashlight-firmware:
status: New → Fix Released
importance: Undecided → High
assignee: nobody → Selene ToyKeeper (toykeeper)
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.