signal strength indicator symbol does not reflect correctly the current strength of the signal

Bug #730537 reported by Conor Curran
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Connection Manager
Triaged
Medium
Kalle Valo

Bug Description

wlan0 IEEE 802.11abg ESSID:"ZyXEL"
          Mode:Managed Frequency:2.462 GHz Access Point: 00:13:49:9B:CB:C7
          Bit Rate=12 Mb/s Tx-Power=15 dBm
          Retry long limit:7 RTS thr:off Fragment thr:off
          Power Management:off
          Link Quality=34/70 Signal level=-76 dBm
          Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0
          Tx excessive retries:0 Invalid misc:13387 Missed beacon:0

ronoc@ronoc-work-laptop:~$ cmcc show ZyXEL | grep Strength
  Strength = 93

According to Kalle I should not have a strength of 93 with a strength of -76db

Revision history for this message
Conor Curran (cjcurran) wrote :

or signal level of -76dBm rather

Revision history for this message
Kalle Valo (kvalo) wrote :

I see the same with connman nightly builds. I don't even see any signal strenght changes with 'cmcc event -t'.

Changed in connman:
status: New → Triaged
importance: Undecided → Medium
assignee: nobody → Kalle Valo (kvalo)