LVM setup fails with cryptic error message if no devices are configured

Bug #1476419 reported by Jason Hobbs
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
OpenStack Cinder Charm
Triaged
Medium
Unassigned
cinder (Juju Charms Collection)
Invalid
Undecided
Unassigned

Bug Description

This is hit if no existing cinder-volumes VG is present, and the devices configured for use in the deployment have existing partition tables and 'overwrite' is set to false. The test for 'vg_found is False and len(new_devices) >' 0 will be false, no volume group will be created, and the vgreduce call will fail with this error:

Volume group "cinder-volumes" not found

Traceback: http://pastebin.ubuntu.com/11911587/

Workaround: This issue can also be avoided by setting the cinder charm's 'overwrite' config field to 'True'.

Suggested fix: the charm should check for the condition where no valid devices are available and no volume group will be created, and should raise an error indicating this before moving on with setup that depends on the volume group's existence.

Tags: oil
Revision history for this message
Corey Bryant (corey.bryant) wrote :

Jason, thanks for the thorough bug report and suggestion. I agree that we should raise an error if there is no volume group found or created, and overwrite is false.

James Page (james-page)
Changed in cinder (Juju Charms Collection):
status: New → Invalid
James Page (james-page)
Changed in charm-cinder:
status: New → Triaged
importance: Undecided → Medium