[2.3, trunk] MAAS power types should be cached by the regiond and not asked all the time
Bug #1748570 reported by
Blake Rouse
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
MAAS |
Fix Released
|
High
|
Blake Rouse |
Bug Description
The regiond should cache the power types that a rack controller has instead of always asking it over and over again.
At the moment the regiond asks the rackd what its power types anytime it needs that information. That information is unlikely to change unless the rackd is reset.
The regiond should cache this information linked to each rackd connection, and once that connection is dropped to clear that information. This will ensure that data is always up to date, will require no database work, and can be backported to 2.3.
Related branches
~blake-rouse/maas:cache-region-to-rack-rpc
- Andres Rodriguez (community): Approve
- MAAS Lander: Needs Fixing
-
Diff: 309 lines (+148/-16)5 files modifiedsrc/maasserver/rpc/regionservice.py (+70/-7)
src/maasserver/rpc/tests/test_regionservice.py (+70/-6)
src/provisioningserver/drivers/nos/registry.py (+1/-1)
src/provisioningserver/rpc/clusterservice.py (+5/-1)
src/provisioningserver/rpc/tests/test_clusterservice.py (+2/-1)
Changed in maas: | |
status: | Triaged → In Progress |
Changed in maas: | |
status: | In Progress → Fix Committed |
Changed in maas: | |
milestone: | 2.4.x → 2.4.0alpha2 |