Fuel UI requires Public IP range for all nodes regardles "Assign public network to all nodes" option
Bug #1376780 reported by
Alexander Fridman
This bug report is a duplicate of:
Bug #1376426: Fuel insist on having Public IP range that is redundant.
Edit
Remove
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
Fuel for OpenStack |
New
|
High
|
Fuel Python (Deprecated) |
Bug Description
Fuel 5.1
Setup with Neutron VLAN segmentation
• 3 x Controllers
• 3 x Computes
• 1 x Cinder
• Option "Assign public network to all nodes" is unchecked
• Public IP range set to 4 IPs
Problems:
1. Fuel fails to deploy with Public IP range of 4 IPs. ERROR: Not enough IP addresses. Public network must have at least 7 IP addresses for the current environment.
2. UI require Public Network assignment while configuring interfaces for Compute and Storage
Changed in fuel: | |
assignee: | nobody → Fuel Python Team (fuel-python) |
milestone: | none → 6.0 |
importance: | Undecided → High |