Fuel UI requires Public IP range for all nodes regardles "Assign public network to all nodes" option

Bug #1376780 reported by Alexander Fridman
10
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Fuel for OpenStack
New
High
Fuel Python (Deprecated)

Bug Description

Fuel 5.1
Setup with Neutron VLAN segmentation
• 3 x Controllers
• 3 x Computes
• 1 x Cinder
• Option "Assign public network to all nodes" is unchecked
• Public IP range set to 4 IPs

Problems:

1. Fuel fails to deploy with Public IP range of 4 IPs. ERROR: Not enough IP addresses. Public network must have at least 7 IP addresses for the current environment.

2. UI require Public Network assignment while configuring interfaces for Compute and Storage

Dmitry Pyzhov (dpyzhov)
Changed in fuel:
assignee: nobody → Fuel Python Team (fuel-python)
milestone: none → 6.0
importance: Undecided → High
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.