Description: Ubuntu lucid (development branch)
Release: 10.04
awn-applets-c-extras - 0.3.9~bzr1944-0ubuntu1
I was expecting to see the current temperature (and to see a variance in values)
The values showing do not change. The applet detected the problem but didn't restart.
ProblemType: Crash
DistroRelease: Ubuntu 10.04
Package: awn-applets-python-core 0.3.9~bzr1944-0ubuntu1
ProcVersionSignature: Ubuntu 2.6.32-17.26-generic 2.6.32.10+drm33.1
Uname: Linux 2.6.32-17-generic i686
Architecture: i386
Date: Sat Mar 27 07:26:06 2010
ExecutablePath: /usr/share/avant-window-navigator/applets/hardware-sensors/hardware-sensors.py
InterpreterPath: /usr/bin/python2.6
PackageArchitecture: all
ProcCmdline: python /usr/share/avant-window-navigator/applets/hardware-sensors/hardware-sensors.py --uid=1269543515 --window=83886131 --panel-id=1
ProcEnviron:
PATH=(custom, no user)
LANG=en_US.utf8
SHELL=/bin/bash
PythonArgs: ['/usr/share/avant-window-navigator/applets/hardware-sensors/hardware-sensors.py', '--uid=1269543515', '--window=83886131', '--panel-id=1']
SourcePackage: awn-extras-applets
Title: hardware-sensors.py crashed with ValueError in read_sensor()
UserGroups: adm admin audio cdrom dialout dip floppy lpadmin mythtv netdev plugdev powerdev pulse pulse-access scanner vboxusers video
Traceback (most recent call last):
File "/usr/share/avant-window-navigator/applets/hardware-sensors/hardware-sensors.py", line 953, in dialog_shown_cb
self.update_values()
File "/usr/share/avant-window-navigator/applets/hardware-sensors/hardware-sensors.py", line 943, in update_values
sensor.read_sensor()
File "/usr/share/avant-window-navigator/applets/hardware-sensors/interfaces/hddtempsensors.py", line 47, in read_sensor
self.value = float(input[3 + 5 * self.__seq_num])
ValueError: invalid literal for float(): ERR
Thanks for your bug report. Fowarded upstream.